제품소개 Products
설치형 가스 검지기
설치형 가스 검지기
설치형 가스 검지기 모델명: Sensepoint XRL

Sensepoint XRL is a fixed point gas leak detector that is designed to
meet the needs of industrial applications. With over 50 years experience
in gas leak detection, Honeywell offers a flexible range of highly-reliable
sensing devices to meet those needs.

► Quick installation

► Rapid configuration

► Simple to operate

► Straightforward to maintain

제품 카달로그
견적문의
제품특징
상세사양

  Choose from a range of mA or Modbus output versions for flexible system design to meet the customers requirements.

  Selectable source or sink current for analog output enables one detector to be suitable for both system configurations.

  The ingress protection of NEMA 4X/IP66 allows units to be installed in outdoor environemtns.

  Simplified maintenance with familiar smartphone technology saves money and time.

  Multi-color visual indicator to show status makes it easier to know the detector status immediately and identify detectors that require attention or are warning of danger.

  Manage the detector without making a physical connection. Remove the need for physical access to hard-to-reach devices. 

  One person calibration without the need to open the detector. Saves time and removes need for hot work permit.

 

PHYSICAL PROPERTIES

DIMENSIONS

118 x 159 x 93 mm ( 4.4 x 6.2 x 3.6 in )

WEIGHT

1400 g (3.1 lb)

CASING MATERIAL

Aluminum alloy LM20 (charcoal or yellow)

INGRESS PROTECTION RATING

IP66, NEMA 4X

LIFETIME

10 years (excludes sensor)

AVAILABLE SENSORS

FLAMMABLE, TOXIC GASES AND OXYGEN RANGES

Combustible: O to 100 % LEL (adjustable between 20 and 100% LEL, Factory calibrated to Methane)

O₂: 0 to 25% vol

CO: O to 300 ppm (adjustable between 50 and 1000 ppm)

H₂: O to 1000 ppm

H₂S Low Range: 0 to 50 ppm (adjustable between 10 and 50 ppm)

H₂S High Range: 0 to 100 ppm (adjustable between 50 and 200 ppm)

POWER SUPPLY

DC INPUT VOLTAGE

24 V DC

AC INPUT VOLTAGE

24 V AC , 50/60 Hz

INRUSH CURRENT

850 mA

OUTPUT

ANALOG OUTPUT

0 to 22 mA

DIGITAL OUTPUT

Modbus RTU

MAXIMUM POWER CONSUMPTION

mA VERSIONS

< 1.5 W (toxic), < 2.6 W (flammable)

MODBUS VERSIONS

< 1.0 W (toxic), < 2.0 W (flammable)

CONNECTION

TYPE

Pluggable rising clamp style, 0.5 to 2.5 mm2, 20 to 13 AWG

USER INTERFACE

VISUAL INDICATOR(Multi-colour LED light ring)

• Flashing green: Normal§

 

• Flashing red: Alarm

 

• Flashing green and yellow: Warning

 

• Flashing yellow: Fault

 

• Solid yellow: Inhibited

 

• Flashing blue: Bluetooth pairing in progress

 

• Solid blue: Bluetooth connection established

WIRELESS INTERFACE

Bluetooth 4.0 (Bluetooth Low Energy). Dedicated mobile app, enabling wireless configuration and maintenance.

Connect up to 10 m (30 ft) away (mobile device dependent). Use a compatible smartphone or other mobile device running Android 4.3 or above.

OPERATING ENVIRONMENT

OPERATING TEMPERATURE

−40 to 65 °C (−40 to 140 °F)

STORAGE TEMPERATURE

0 to 30 °C (32 to 86 °F)

HUMIDITY

0 to 99% (non-condensing)

ATMOSPHERIC PRESSURE

90 to 110 kPa

CERTIFICATIONS

ELECTRICAL SAFETY

EN/IEC/UL 61010-1
CSA C22.2 No. 61010-1-12

EMC

EN 50270:2015

RADIO

RED, FCC, IC

HAZARDOUS AREA

• ATEX
II 2 GD
Ex db IIC T6 Gb
Ex tb IIIC T85 °C Db
Tamb −40 to +65 °C

 

• IECEx
Ex db IIC T6 Gb
Ex tb IIIC T85 °C Db
Tamb −40 to +65 °C

 

• cULus
Class I, Division 1 & 2, Groups B, C and D
Class II, Division 1 & 2, Groups E, F and G
Class I, Zone 1, AEx db IIC T6
Zone 21, AEx tb IIIC T85°C, IP6X
Ex db IIC T6 GbX
Ex tb IIIC T85°C DbX
Tamb −40 to +65 °C, Temp Code T6

GAS PERFORMANCE

CSA C22.2 No.152-M1984, UL 2075, AS 1668.2

 

목록으로