제품소개 Products
Precision Temperature Scanner
Precision Temperature Scanner
Precision Temperature Scanner 모델명: 1586A

► Temperature Range : −200 °C to 1200 °C

► Temperature Accuracy : 0.008 °C at 0 °C

► Display resolution : 6 1/2 digits

► Resolution : 0.001 °C

► 다채널 구성 가능

 

제품 카달로그
견적문의
제품특징
상세사양

1586A Super-DAQ Precision Temperature Scanner

The 1586A Super-DAQ collects time-stamped precision temperature and electrical measurements for data analysis by technicians, engineers,

and quality control personnel to verify process control, analyze interactive systems, ensure conformance to quality standards,

or to correlate related events for R&D or troubleshooting. Measurement data and statistics can be viewed in tabular format for all active channels.

With the graphing feature, up to four channels can be plotted at the same time, making it easy to quickly assess test setup and results before analyzing the data on a PC.  

When configured with the DAQ-STAQ Multiplexer, the Super-DAQ has the accuracy of the best benchtop reference thermometer readouts for calibration of PRTs, RTDs, thermistors, or thermocouples.

Lab efficiency can be increased when the Super-DAQ is connected to a Fluke Calibration drywell or bath and Automated Sensor Test routines are run.

The 1586 is ideal for a number of applications such as thermal mapping, temperature validation, process sensor calibration, and more.

These applications are found in a various industries including pharmaceutical, biotechnology, food processing, aerospace, and automotive.

Some temperature data acquisition applications require compliance to government and standards agency requirements.

TQSoft and TQAero thermal validation software help engineers, technicians and lab managers to meet the key guidelines for temperature data collection.

These software solutions provide a complete qualification, reporting, documentation, and audit trail management system.

General Specifications

Mains Voltage 100 V Setting: 90 V to 110 V
120 V Setting: 108 V to 132 V
220 V Setting: 198 V to 242 V
240 V Setting: 216 V to 264 V
Frequency 47 Hz to 440 Hz
Power Consumption  36 VA peak (24 W average)
Environment Temperature Operating: 0 °C to 50 °C
Full accuracy: 18 °C to 28 °C
Storage: −20 °C to 70 °C
Warm-up: 1 hour to full accuracy specifications
Relative Humidity (non-condensing) Operating:  0 °C to 30 °C <80 %;
                   30 °C to 50 °C <50 %
Storage: −20 °C to 70 °C <95 %
Altitude Operating: 2,000 m
Storage: 12,000 m
Vibration and Shock  Complies with MIL-PRF-28800F Class 3
Channel Capacity Total analog channels: 45
Voltage/resistance channels: 41
Current channels:  5
Digital I/O: 8 bits
Totalizer: 1
Alarm outputs: 6
Trigger input: 1
Channel Input Connector Types 1586A Channel 001 (front panel): gold pins, bare wire, spade lugs, banana plugs
DAQ-STAQ Multiplexer: gold pins, bare wire, mini spade lugs, mini banana plugs, mini-jack thermocouple
High-Capacity Module: gold pins, bare wire
Input Protection  50 V all functions, terminals and ranges
Math Channels Number of channels: 20
Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum
Triggers interval, external (trigger input), alarm, remote (bus), manual, automated test
Memory Scan data RAM: 75,000 readings with timestamp
Data/Setup flash memory: 20 MB
USB Host Port Connector type: Type A
Function: Memory
File system: FAT32
Memory capacity: 32 GB
USB Device Port Connector type: Type B
Class: Instrument
Function: Control and data transfer
Command protocol: SCPI
LAN Function: Control and data transfer
Network protocols: Ethernet 10/100, TCP/IP
Command protocol: SCPI
RS-232 Connector: D-sub 9 pin (DE-9)
Baud rates: 1200, 2400, 4800, 9600, 19200, 38400
Function: Temperature source control output
Dimensions Height: 150 mm
Width: 245 mm
Depth: 385 mm Weight: 6 kg (typical configuration)
Shipping Weight: 9.5 kg (typical configuration)
Conformity CE, CSA, IEC 61010 3rd ed.